To: Slim Spurling
Subject: Data Analysis of Pollution Reduction Device (R-2 Unit)
Methodology: A device that was developed by Slim Spurling, Bill Ried and Bob Dratch
was tested to determine if it reduced air ozone, carbon monoxide and
to determine
if it decreased particles in the air. Greg Orton monitored the
device and recorded
the time in a log book when he turned it off and on.
Location: The testing was done in Fort Collins, CO.
Time of Testing: September, October and November of 1995.
Data Collection: The City of Fort Collins supplied the hourly levels of ozone,
carbon monoxide and air visibility
Results: September 1995
Carbon Monoxide levels in the on setting: 3101/371 = 8.39 average
Carbon Monoxide levels in the off setting: 3002/330 = 9.10 average
8.5% less carbon monoxide in the on position.
Ozone levels in the on position: 6712/371 = 18.09
Ozone levels in the off position: 6597/330 = 19.99
10.5% less ozone in the on position.
Hours on: 300
Hours off: 277
Ozone in on position: 4017/309 = 13
Ozone in off position: 7980/424 = 18.82
44.8% more ozone in the off position.
Results: November 1995
Carbon monoxide levels in on position: 3271/356 = 9.19 average
Carbon monoxide levels in off position: 3885/309 = 12.39 average
34.6% more carbon monoxide in off position.
Ozone levels in on position: 3068/343 = 8.94 average
Ozone levels in off position: 4504/309 = 14.58 average
63.1% more ozone in off position.
Overall comments: The study does show a trend but needs to be expanded to a large level.
Future studies should be better controlled regarding day time and night time.
There may be errors in addition.
21.4% higher reading in the off position.
Transmiometer Sigma Reading (TS) - indicates variation for wind.
TS levels in the on position: 3269.9/300 = 10.89
TS levels in the off position: 2397.2/277 = 8.7
20.1% less in the off position. This means there was less variation of wind in the off position.
Corr B-ext - Corrects for wind and humidity. This is a more reliable figure for measuring gas and particles than TA.
On 282 hours.
Off 281 hours.
Corr- ext levels in on position: 42.45/282 = 0.15
Corr- ext levels in off position: 23.38/281 = 0.08
47% less in off position. Water vapor increased.
Summary in September: Carbon monoxide and ozone were higher in off position. Corr B-ext factor was lower in off position. Statistical analysis was not performed to determinie if these results were scientifically significant.
Results: October 1995
On: 309 hours
Off: 423 hours
Carbon monoxide in on position: 2968/309 = 9.61
Carbon monoxide in off position: 4396/423 = 10.39
8.1% more carbon monoxide in off position.